Impulse Current Generator
Product Overview
The VERXON Impulse Current Generator is designed to evaluate the ability of electrical equipment and protective devices to withstand surge currents. It can generate standard high-current, steep-front and long-duration impulse current waveforms for different test applications.
The waveform, maximum current, energy and measurement and control configuration are selected according to the test object and project requirements.
Applications
Energy and residual voltage tests on zinc oxide surge arrester units
Complete surge arrester testing
Lightning protection equipment testing
Aircraft lightning-current resistance model testing
High-current impulse testing in laboratories and research institutions
Supported Waveforms
1/20µs steep-front impulse current
4/10µs high-current impulse
8/20µs standard impulse current
18/40µs and 30/80µs operating current waveforms
10/350µs lightning current waveform
2000µs, 3200µs and 6400µs long-duration rectangular current waveforms
200–230µs half-wave near-sinusoidal current
A, B, C, D and H current waveforms for aircraft model testing
Product Features
Maximum current up to 200kA for the 4/10µs waveform
Maximum current up to 120kA for the 8/20µs waveform
Supports complete surge arrester testing for voltage classes up to 1100kV, subject to system configuration
Two selectable triggering methods for synchronized and reliable operation
Thyristor-based constant-current charging
Integrated computer, PLC and fiber-optic measurement and control
Optional oscilloscope or high-speed data acquisition system
Compact and mobile configurations available for onsite applications
Waveform and system parameters configurable according to project requirements
Frequently Asked Questions
Which impulse current waveforms can the system generate?
The generator can be configured for standard waveforms such as 4/10µs, 8/20µs and 10/350µs, as well as steep-front, operating-current and long-duration current waveforms.
What is the maximum output current?
The available configuration supports up to 200kA for the 4/10µs waveform and up to 120kA for the 8/20µs waveform.
Can the system test complete surge arresters?
Yes. A suitable configuration can support testing of complete zinc oxide surge arresters for voltage classes up to 1100kV.
How is the system controlled and measured?
The system can integrate computer and PLC control, fiber-optic communication and an oscilloscope or high-speed data acquisition system.
Can a mobile impulse current system be supplied?
Yes. Compact and mobile systems can be configured according to onsite test requirements.